1.
Int. j. odontostomatol. (Print) ; 11(1): 53-60, abr. 2017. ilus
Article in Spanish | LILACS | ID: biblio-841016

ABSTRACT

Se realizó un estudio in vitro donde se evaluaron once sistemas adhesivos, para establecer si las condiciones de trabajo clínico favorecen su eficiencia. Se plantea que los sistemas adhesivos autoacondicionantes presentan menor estabilidad térmica que los convencionales. Determinar el comportamiento térmico de once sistemas adhesivos sometidos a diferentes rangos de temperatura en ambientes con 100 % de humedad, agua acidulada, humedad ambiental, saliva artificial y la correlación con su composición. Se utilizaron adhesivos autograbantes y convencionales, se prepararon muestras en cápsulas de aluminio pequeñas y se fotopolimerizaron con una lámpara LED. Se les realizó el estudio de espectroscopía infrarrojo con transformada de Fourier (FT-IR), asignando las bandas de absorción de los grupos funcionales orgánicos de cada compuesto, correspondientes a los grupos químicos que poseen. Posteriormente fueron sometidas a examen termogravimétrico entre temperatura ambiente y 500 °C para establecer un patrón de comportamiento térmico en ambiente inerte y luego de permanecer en agua acidulada, 100 % humedad, humedad ambiental y saliva artificial. Los termogramas informaron las temperaturas de descomposición y los porcentajes de pérdida de masa. Se correlacionaron los resultados del estudio de FT-IR infrarrojo con el comportamiento térmico de los sistemas adhesivos. Se observó pérdida de masa, eficiencia de la polimerización y cantidad de masa residual. Se observaron dinámicas de degradación diferentes por el diseño de las curvas y por los cambios en la línea base. Conclusión: Los sistemas adhesivos de ambos grupos analizados, presentaron elevado grado de polimerización. Sin embargo, el efecto producido por las condiciones a las cuales fueron sometidos, depende del tipo de adhesivo, siendo que, los adhesivos convencionales, a diferencia de los autoacondicionantes, se degradan en menor extensión, reflejado por su mayor estabilidad térmica.


An in vitro study of eleven adhesive systems was carried out to establish if clinical work conditions could improve their efficiency. It has been observed that self-etch adhesive systems have less thermal stability than conventional ones. As a consequence, early replacement of unsatisfactory aesthetic restorations is needed. The objectives of this work were to determine the thermal behavior of eleven polymeric adhesive systems under different rates of temperatures and a variety of conditions such as 100 % humidity, presence of acidulated water (pH 3), environmental relative humidity and artificial saliva. Another aim was to establish if these factors are correlated with the adhesive systems composition. For each type of adhesive system, samples were prepared in small aluminum caps and polymerized with a LED lamp. All samples were analyzed with the Fourier-Transform Infrared Spectroscopy (FT-IR) method, which assigned absorption bands to organic functional groups of each compound corresponding to their chemical type. Subsequently, a thermogravimetric analysis was performed in a range temperature from room temperature to 500 °C in order to establish thermal behavior in an inert environment and after staying in acidulated water, 100 % humidity, environmental humidity and artificial saliva. Thermograms were obtained to collect data about decomposition temperatures and loss of mass percentages. The FT-IR study results were correlated with the adhesive systems thermal behavior. Thermogram images showed loss of mass, polymerization efficiency and residual mass amount. The different degradation dynamics were analyzed according to curve designs and baseline changes. Both groups of adhesive systems revealed high polymerization degrees. Nevertheless, the effect produced by the conditions in which they were subjected depends on the type of adhesive. Conventional adhesives, in contrast to self-etch adhesives, degraded in a minor extension as a result of their higher thermal stability.


Subject(s)
Dental Bonding , Dentin-Bonding Agents/chemistry , Hydrolysis , Temperature , Composite Resins/chemistry , Hydrogen-Ion Concentration , In Vitro Techniques , Materials Testing , Spectroscopy, Fourier Transform Infrared
2.
Braz. dent. j ; 25(6): 472-478, Nov-Dec/2014. tab, graf
Article in English | LILACS | ID: lil-732254

ABSTRACT

To evaluate the microtensile bond strength (µTBS) of a fluoride-containing adhesive system submitted to a pH-cycling and storage time regimen for primary outcomes. As secondary outcomes the fluoride released amount was evaluated. Twelve dentin surfaces from sound third molar were divided into 2 groups according to adhesive systems: Clearfil SE Protect (PB) and Clearfil SE Bond (SE). Sticks obtained (1.0 mm2) from teeth were randomly divided into 3 subgroups according to storage regimen model: immediate (24h); 5-month deionized water (W); and pH-cycling model (C). All sticks were tested for µTBS in a universal testing machine. Fluoride concentration was obtained from 1-4 days and 30-day in W and 1-4 days in demineralization (DE)/remineralization (RE) solutions from C, using a fluoride-specific electrode. µTBS and fluoride released data were, respectively, submitted to ANOVA in a split plot design and Tukey, and Friedman' tests (a=0.05). There was no significant interaction between adhesive system and storage regimen for µTBS. W showed the lowest µTBS values. There was no significant difference between 24 h and C models for µTBS. There was no significant difference between adhesive systems. Failure mode was predominantly cohesive within composite for the 24 h and W, for the C group it was mixed for SE and cohesive within composite for PB adhesive system. Fluoride concentrations in the DE/RE solutions were less than 0.03125 ppm and not detected in W. In conclusion, the fluoride-containing adhesive system performed similarly to the regular one. Hydrolytic degradation is the main problem with both adhesive systems, regardless of fluoride contents.


O objetivo principal desse estudo foi avaliar a resistência de união à microtração de dois sistemas adesivos (com e sem flúor) após a ciclagem de pH e armazenagem em água deionizada. A quantidade de flúor liberada foi avaliada secundariamente. Doze terceiros molares hígidos foram separados em 2 grupos de acordo com o sistema adesivo: Clearfil SE Protect - com flúor (PB) e Clearfil SE Bond - sem flúor (SE). Os palitos (1 mm2) obtidos do mesmo dente foram aleatoriamente divididos em 3 subgrupos de acordo com o meio de armazenagem: em água deionizada por 24h ou 5 meses e ciclagem de pH. Os palitos foram tracionados em uma máquina de ensaio universal a 0,5 mm/min. A concentração de flúor foi analisada em água deionizada (1-4 dias e 30 dias) e na solução remineralizadora e desmineralizadora (1-4 dias) usando um eletrodo específico. Os dados de resistência de união e liberação de flúor foram, respectivamente, submetidos à Análise de Variância em esquema de parcela subdividida e ao teste de Friedman (a=0,05). Não houve nenhuma interação significativa na resistência de união entre os sistemas adesivos e os meios de armazenagem. Os menores valores de resistência de união à microtração foram encontrados para os palitos armazenados em água deionizada. Não houve nenhuma diferença significativa nos valores de resistência de união após 24h e ciclagem de pH. Nenhuma diferença significativa na resistência de união foi observada entre os 2 sistemas adesivos. O modo de falha foi predominantemente coesivo em compósito para os grupos armazenados em água por 24h ou 5 meses para ambos os sistemas adesivos. No grupo submetido à ciclagem, a falha foi mista para o SE e coesiva em compósito para o PB. A concentração de flúor nas soluções DE/RE foi menor que 0,03125 ppm e não detectada em água deionizada. Concluindo, o sistema adesivo com flúor (PB) apresentou performance similar ao sistema adesivo sem flúor (SE). A degradação hidrolítica foi o principal fator para ambos os sistemas adesivos, independente da adição de flúor.


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Antineoplastic Agents/administration & dosage , Floxuridine/administration & dosage , Antineoplastic Agents/toxicity , Drug Administration Schedule , Drug Evaluation , Drug Tolerance , Floxuridine/toxicity , Isomerism , Neoplasms/drug therapy
3.
Acta cient. venez ; 54(1): 18-27, 2003. ilus, tab, graf
Article in Spanish | LILACS | ID: lil-351687

ABSTRACT

Se estudió la degradación hidrolítica in vitro de suturas de Poliglactin 910 utilizando un buffer de fosfato , pH= 7,4, a 37 °C. La degradación fue evaluada a través de la perdida en peso, cambio en las propiedades térmicas, morfología y propiedades mecánicas de las suturas sometidas a hidrólisis. Después de 10 semanas, los resultados obtenidos de la pérdida en peso y pH sugieren la difusión de especies de bajo peso molecular al medio de reacción como consecuencia del ataque hidrolítico a los grupos éster en el polímero. La disminución de las propiedades mecánicas, tanto el esfuerzo de ruptura como el modulo, junto con los resultados anteriores sugieren que el proceso de escisión de cadenas procede en dos etapas: la primera ocurre en las zonas amorfas y la segunda en las zonas cristalinas. El estudio de la morfología correspondiente a la superf icie de las sutura revela un mecanismo de degradación heterogéneo por capas.


The hydrolytic degradation of bioabsorbable Poliglactin 910 was studied in a phosphate buffer solution, pH= 7,4, at 37 °C. The degradation was evaluated by analyzing the changes in weight loss, pH, DSC, mechanical properties and morphological changes. After 10 weeks, the weight loss and pH changes suggested diffusion of low molecular weight chain segments into the reaction medium as a consequence of the breaking of ester bonds in the material. Breaking stress and Young Modulus decrease, indicating that chain scission proceeded in two steps: the first ocurring in the amorphous regions within the intermicrofibrillar space; the second in the crystalline regions. Surface morphological changes suggest a heterogeneous degradation mechanism by layers.


Subject(s)
Polyglactin 910 , Biocompatible Materials , Biodegradation, Environmental , Materials Testing , Microscopy, Electron, Scanning , Hydrogen-Ion Concentration , Hydrolysis